Vo2max Measurement Using Bleep Test with Infrared Sensor
Abstract
The purpose of this study was to develop a measuring device to measure maximal aerobic capacity by using digital bleep test with infrared sensor and motion analysis system software to obtain a more accurate, precise, and efficient assessment result in conducting the test. The method used in the study was R & D (Research and Development) method. This research was conducted in collaboration with a team of experts of various specific fields so that the development of this simple prototype could create a validated product before mass production is conducted. The result of this study will create a digital-based measuring instrument that has been valid through validity test. Conducting a study that develops a product could prevent error and human error during the test. Therefore, a more efficient process and a more accurate result can be obtained compared to manual testing.
Abstrak
Penelitian ini bertujuan untuk mengembangkan alat ukur Maximal aerobic capacity melalui bleep test berbasis digital dengan menggunakan sensor infrared dan software motion analysis system supaya mendapatkan hasil penilaian yang lebih tepat, akurat dan efesiensi pengerjaan dalam melakukan tes. Metode penelitian yang digunakan oleh peneliti adalah metode R&D (research and Development), bekerjasama dengan tim pakar atau ahli dalam berbagai bidang tertentu supaya dalam pengembangan prototype sederhana ini yang dapat menciptakan suatu produk yang dapat divalidasi sebelum diproduksi secara massal. Hasil dari penelitian ini akan menciptakan suatu alat ukur berbasis digital yang sudah dilakukan uji validitasnya dengan hasil dinyatakan VALID. Dengan adanya penelitian yang mengembangkan suatu produk dapat menghindari kesalahan atau Human error dalam pengerjaan tes ,mendapatkan hasil yang akurat di bandingkan tes secara manual dan pengerjaan lebih efesien.
Keywords
Full Text:
PDFReferences
Alahakone, A. U. (2009). 2009 International Conference of Soft Computing and Pattern Recognition A Real Time Vibrotactile Biofeedback System for Improving Lower Extremity Kinematic Motion During Sports Training, 616–621. http://doi.org/10.1109/SoCPaR.2009.120
Bruno, P. . S., Bertucci, D. R., & Inaian, P. (2013). Is the VO 2 max that we measure really maximal ?, 4(August), 1–5. http://doi.org/10.3389/fphys.2013.00203
Dai, F., Cogi, N. H., Ugo, E., Heinzl, L., Costa, E. D., Canali, E., & Minero, M. (2015). Validation of a fear test in sport horses using infrared thermography. Journal of Veterinary Behavior: Clinical Applications and Research, 10(2), 128–136. http://doi.org/10.1016/j.jveb.2014.12.001
Engineering, M., & Bahru, J. (2013). Application of Infrared Sensor for Shape Detection, 145–147.
Haryono, S., & Pribadi, F. S. (2012). Pengembangan Jump Power Meter Sebagai Alat Pengukur Power Tungkai, 2.
Lee, J. B., Mellifont, R. B., & Burkett, B. J. (2010). The use of a single inertial sensor to identify stride , step , and stance durations of running gait. Journal of Science and Medicine in Sport, 13(2), 270–273. http://doi.org/10.1016/j.jsams.2009.01.005
Leger, L. A., Mercier, D., Gadoury, C., & Lambert, J. (n.d.). run test for aerobic fitness The multistage 20 metre shuttle run test for aerobic fitness. Journal of Sport Sciences, (May 2013), 37–41.
Longo, A. F., Aquilino, G. D., Cardey, M. L., & Lentini, N. A. (2016). ˙ O 2 max assessment in athletes : A thorough method comparison study between Yo-Yo test and direct measurement ଝ. Apunts Medicina de l’Esport, (xx), 1–6. http://doi.org/10.1016/j.apunts.2016.07.001
Paradisis, G. P., Zacharogiannis, E., Mandila, D., & Smirtiotou, A. (2014). Multi-Stage 20-m Shuttle Run Fitness Test , Maximal Oxygen Uptake and Velocity at Maximal Oxygen Uptake, 41, 81–87. http://doi.org/10.2478/hukin-2014-0035
Radakovic, R., Dopsaj, M., R., V., Leontijevic, B., N., M., & Filipovic, N. (n.d.). The reliability of motion analysis of elite soccer players during match measured by the Tracking Motion software system.
Sulaiman, N., Akmal, M., Nasir, M., Adnan, R., Misdan, M., & Ahmad, H. (2011). Criterion Validity of Yoyo Intermittent Endurance Test in Estimating Maximal Oxygen Consumption among Malaysian Elite Football Players . IEEE Colloquium on Humanities, Science and Engineering Research, (Chuser), 281–284.
Ueda, M., Negoro, H., Kurihara, Y., & Watanabe, K. (2013). Measurement of Angular Motion in Golf Swing by a Local Sensor at the Grip End of a Golf Club, 43(4), 398–404.
DOI: https://doi.org/10.17509/jpjo.v4i1.16015
Refbacks
- There are currently no refbacks.
Copyright (c) 2019 Agus Rusdiana, Iman Imanudin, Angga Muhamad Syahid, Ricky Wibowo
This work is licensed under a Creative Commons Attribution-ShareAlike 4.0 International License.